 | | autostart of program in mindstorm
|
|
You can use my free RCX Command Center. You can select the program, run it or stop it, and even run individual tasks. (Of course, it also does a lot more.) See my web page for more info: (URL) Overmars (...) (28 years ago, 10-Dec-98, to lugnet.robotics)
|
| |
 | | Communicating with IR tower
|
|
The standard way for doing this is to use variable 0 on the RCX. Te robot can set it to a specific valu when it needs something. The PC can use the SetEvent command and the VariableChange event handler to check whether the variable changes. (...) (28 years ago, 10-Dec-98, to lugnet.robotics)
|
| |
 | | Delphi developers
|
|
RCX Command Center was written in Delphi using the spirit.ocx. It work very easy. (Only note that the On command to switch motors on is called On_ because on is a reserved word in Delphi.) But if you want to write programs to download to the RCX, I (...) (28 years ago, 10-Dec-98, to lugnet.robotics)
|
| |
 | | CM: MotorCurrent
|
|
For the Cybermaster unit, it is possible to monitor the current of the external motor, measured in milliamps. I assume this can be used to detect when the motor is stalled. Do anybody know the typical values of MotorCurrent when the motors is o (...) (28 years ago, 10-Dec-98, to lugnet.robotics)
|
| |
 | | Re: Communicating with IR tower
|
|
Hi John, I've been doing this for a while with the Cybermaster. You can simple use the SetVar and Poll commands in immediate mode via the OCX to read and set variables in the brick. Add a bit of handshaking and you have a communications mechanism (...) (28 years ago, 10-Dec-98, to lugnet.robotics)
|
| |
 | | effect of motor speeds
|
|
I noticed that settting the motor speed does not seem to have much efect on the speed the robot is moving: 0 = slow 1 = faster 2 = slighly faster than 1 3-7 = about equal to 2 Am I doing something wrong? Or is this standard behavior? Mark Overmars (28 years ago, 10-Dec-98, to lugnet.robotics)
|
| |
 | | Re: CM: MotorCurrent
|
|
I only made one test with it, and by the looking at the results I couldn't tell if the motor running loaded, but I may be wrong! The result of the function seems to be: .If no motor is attached, the result is zero. .If a motor is attached and not (...) (28 years ago, 10-Dec-98, to lugnet.robotics)
|