In article <Fwo5xB.M16@lugnet.com>, "Ben Erwin" <ben@alum.mit.edu>
wrote:

ok, so i'm getting a little closer to answering my own question, but i'm
still
stuck.

if i write a new robolab program to take 10 points of light data and then
upload it with VB, those 10 points get put into slots 10-20 in the
datalog,
and points 1-10 in the datalog remain intact for some reason.  Also,
these
light sensor values are labeled "variable 23" -- but i wouldn't put it
past
chris to have called the light sensor 'variable 23' in robolab for who
knows
what reason.  i'll have to ask him.


I think chris is putting some other info in the datalog.  I poked at
this briefly when using an early version of Robolab 2.0, but I don't
recall the exact details.  I think it comes from Robolab trying to use
the datalog to record multiple channels of info, so it add in values
describing how the datalog is used.

I be the reason he logs a variable is that he really wants to put a
constant into the log, but that isn't allowed, so you move the constant
into a scratch variable, then log the var.

anyway, when i then go and download a data-taking program for light and
temp
data (the one posted the previous message) and then upload THAT with VB
or
NQC, that data is tacked on to the VERY END of the datalog, and looks
pretty
normal (with the addition of a .ClearTimer 0, which I had forgotten).

My guess is that the VB call to SetDatalog isn't doing anything.  Try
running this brief NQC program - it should erase the datalog completely:

task main()
{
  CreateDatalog(0);
}

If the datalog symbols on the LCD are still lit/flashing, then for some
mysterious reason your RCX won't erase its datalog.

Then try your VB program.  If the datalog doesn't exist (no LCD symbols
lit/flashing, and an upload reveals no data), then the VB call is hosed.
I took a brief look at your code and I think it should work, but I'm not
much of a VB or Spirit.ocx expert.

Dave

--
reply to: dbaum at enteract dot com



Message has 1 Reply:
  Re: VB Upload Problem
 
You could always check how big your datalog is by uploading the first point of the datalog in VB. The third element of the first point (point 0) is the size of the datalog. Throw that in a databox and see what it gives you. I would agree that VB (...) (24 years ago, 26-Jun-00, to lugnet.robotics, lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)

Message is in Reply To:
  Re: VB Upload Problem
 
ok, so i'm getting a little closer to answering my own question, but i'm still stuck. if i write a new robolab program to take 10 points of light data and then upload it with VB, those 10 points get put into slots 10-20 in the datalog, and points (...) (24 years ago, 24-Jun-00, to lugnet.robotics, lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)

11 Messages in This Thread:



Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact

This Message and its Replies on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

Custom Search

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR