  Re: Sensor monitoring
 
(...) that (...) What about using homebrew light sensors made from CdS photoresistors? Seems like it would be possible to multiplex them since they don't require power. (28 years ago, 23-Jan-99, to lugnet.robotics)
 
  Re: RCX message's
 
Rudi Slomp skrev i meddelandet <36A92700.4A0B@iaehv.nl>... (...) I think these are Mindstorms specific - sending messages through the IR port. -- Anders Isaksson, Sweden BlockCAD: (2 URLs) (28 years ago, 23-Jan-99, to lugnet.robotics)
 
  Re: Ultrasonic sensor
 
(...) Firstly, it looks like the sensor board can be powered from the HB using the motor power header (J13). This is good, because the two should share a common ground. Based on the schematic and the web page description, it looks like this type of (...) (28 years ago, 23-Jan-99, to lugnet.robotics.handyboard)
 
  Re: senor signal line back to HD
 
(...) The sensor should be grounded to the HB. (...) Oh yes. Quite a few messages this past week suggest how to avoid frying your sensor ports with excessive voltage. -- Will , , __@_/ \_@__ |/ | /__, o @_/ )\ ) ( \ (\/\\, ~~~...~~~ ' ` ~~~...~~~ ` (...) (28 years ago, 23-Jan-99, to lugnet.robotics.handyboard)
 
  Stack Overflow
 
Hi everyone: I'm trying to download a rather large chunk of code to the HandyBoard, and I'm having a problem when I exceed a certain number of instructions in a procedure I'm running. When I try to download the code, I get the error "yacc stack (...) (28 years ago, 23-Jan-99, to lugnet.robotics.handyboard)
 
  batteries port
 
dear readers, i am current using power supply of around 15 to 20 volts to supply to my HB. i remove the 9.6 batteries supply cause it does not have the strength to drive my 30 v dc motor. will it affect the board? jass (28 years ago, 23-Jan-99, to lugnet.robotics.handyboard)
 
  Re: Sensor monitoring
 
Mark Dollar wrote in message ... (...) There is no passive way to multiplex analog values into an analog value. With extra electronics you could threshold each CdS sensors level to a binary signal and then convert them to back to analog. For an (...) (28 years ago, 23-Jan-99, to lugnet.robotics)
 
  Re: DATALOG and C
 
(...) Worse than that, the IR tower will not receive a message unless it is currently powered up. Since the IR tower automatically powers down a few seconds after transmitting data, you will not be able to receive data unless the C program (...) (28 years ago, 23-Jan-99, to lugnet.robotics)
 
  Re: Stack Overflow
 
Hi there, In my humble opinion, I suspect that the problem is with Interactive C.. Try a newer or older version. What version are you using, by the way ? To quote Levine et al, "lex & yacc", 2nd Ed, O'Rielly & Assoc page 259: "yacc stack overflow (...) (28 years ago, 23-Jan-99, to lugnet.robotics.handyboard)
 
  Memory Map with Expansion board
 
Hi Folks, I was just reading the FAQ and encountered the part about the memory map. Does anyone know how the expansion board maps as it is not included in the memory map in the FAQ? Thanks, Chris Prosser (28 years ago, 23-Jan-99, to lugnet.robotics.handyboard)