 | | Re: RCX Virus?
|
| (...) I use rechargeable batteries too but I use Rayovac Renewals, Manganese Alkaline which have a full-charge open-circuit voltage of 1.55 and a fairly linear discharge curve (sloping downward, of course). I don't use NiMH rechargeables because (...) (21 years ago, 16-May-06, to lugnet.robotics)
| | |  | | Re: RCX Virus?
|
| Hello Jonathan, (...) No, it is extremely improbable! Here is the only "virus" for RCX I know: (URL) it requires some cooperation so that it can spread! (...) I don't think so. Did you have very heavy load on all three motor outputs? if so, there is (...) (21 years ago, 16-May-06, to lugnet.robotics)
| | |  | | Re: RCX Virus?
|
| (...) Some more info about the problem: My RCX is 2.0 and I bought it 4-5 years ago. It's been on the shelf for a while (2-3 months) and I've always used rechargeable batteries. The ones I'm using now are 2000mA NiMH. I installed the firmware both (...) (21 years ago, 16-May-06, to lugnet.robotics)
| | |  | | Re: RCX Virus?
|
| (...) I seem to remember that as well, but it was in either Java or Ultimate Robolab IMS. What language/firmware are you using? (21 years ago, 16-May-06, to lugnet.robotics)
| | |  | | Re: RCX Virus?
|
| (...) I think it is very doubtful. I have not heard of any actual evidence of an RCX virus. What software are you using? How old is the RCX? Are you using a Ver. 1.0 with A/C input? Are you using an external power transformer? Can you borrow another (...) (21 years ago, 16-May-06, to lugnet.robotics)
| |