  Re: Wall Following
 
Chris, I got the same problems with the IR detection. I read somewhere that this is a problem when you use IC and multi processes. The solution could be a "hog_processor()" statement in the IR routine. My question to you is. How will you solve the (...) (29 years ago, 29-Mar-98, to lugnet.robotics.handyboard)
 
  using 7.2v battery with HB
 
this actually should be fine. the characteristic of nicads is to have a fairly level output voltage as they discharge, and then drop off sharply when the power's all gone. so it should be no problem. fred (29 years ago, 29-Mar-98, to lugnet.robotics.handyboard)
 
  Re: 7.2V vs 8.4V (fwd)
 
Wait! Sorry, I was confused! I thought the HB originally battery was 7.2V. Silly me. :-/ Why didn't anyone correct me??? Well, you kinda caused the confusion though. You mean 7.2V vs. 9.6V? or 8.4V vs. 9.6V? ...cuz 9.6V is the original eight 1.2V (...) (29 years ago, 28-Mar-98, to lugnet.robotics.handyboard)
 
  Re: 68HC11 register locations?
 
(...) The correct actual addresses are indeed all in the $10xx range. When you index off either the X or Y register, the offset value is only 8 bits, or 0 to $FF. This is why you're getting the warning messages, the high order $1000 is being (...) (29 years ago, 28-Mar-98, to lugnet.robotics.handyboard)
 
  Re: h-bridge
 
Wirz Electronics has 3 different types in kits (URL) dealt with them and I received good service from them. (...) (29 years ago, 28-Mar-98, to lugnet.robotics.handyboard)