 | | Re: i neeeeeed help! can't logon to the lego site
|
|
(...) "Can't log on to certain URLs" and "IR Tower light stays on..." for me were two connected problems. I solved them, thanks to the Eastman Kodak webmaster and tech support at my ISP, Sympatico.ca. They found incorrect settings on my ethernet (...) (25 years ago, 31-May-01, to lugnet.robotics)
|
| |
 | | Re: problem with floating point numbers (legOS 0.2.5)
|
|
(...) Okay, good to hear the problem has been resolved. Hopefully the person who ran into this problem before you also found something that worked in the end. -Kekoa (25 years ago, 31-May-01, to lugnet.robotics.rcx.legos)
|
| |
 | | Handy Board web site ISP switch
|
|
Hi all, I'm switching to a new ISP to host the Handy Board web site. During the next few days, the URL might not resolve properly. If you have trouble loading handyboard.com, you can use (URL) . This works now. Hopefully the switch-over will be (...) (25 years ago, 31-May-01, to lugnet.robotics.handyboard)
|
| |
 | | Another good day for Mecha
|
|
Yes today was another good day for Mecha. Today I brought my big Mech-bot to New York City's Chelsea Vocational/Charter High School. Classes that participated in using Lego Mindstorms in the clasroom got to see what Lego can do and ask questions (...) (25 years ago, 31-May-01, to lugnet.build.mecha, lugnet.robotics, lugnet.edu)
|
| |
 | | Re: Custom Firmware, IR Problems, and Dead RCXs (long)
|
|
In lugnet.robotics, Matthias Jetleb writes: <snip...> (...) One important point that I haven't seen mentioned here is that the RCX AC adaptor input is labelled "9-12V~", which is AC, not DC. I have used the transformer that comes with the 9V train (...) (25 years ago, 30-May-01, to lugnet.robotics)
|
| |
 | | Re: IR Tower Use
|
|
If you're using Linux, see if Linux IR tools can chat with a tower -- or if some other RS-232 IR device can chat with a Lego device. I haven't had time to do such tests yet. (25 years ago, 30-May-01, to lugnet.robotics.rcx, lugnet.robotics, lugnet.off-topic.geek)
|
| |
 | | Re: Custom Firmware, IR Problems, and Dead RCXs (long)
|
|
Another way of working around the high power and range problems would be an IR repeater. Usually these are used to extend the range of IR remote controls to another room or to a stage. (URL) two-way device might be needed here -- I've also seen some (...) (25 years ago, 30-May-01, to lugnet.robotics)
|
| |
 | | Re: Custom Firmware, IR Problems, and Dead RCXs
|
|
(...) Gee, could you tell I don't have a block diagram of the innards of the RCX? 95% of the work I've done with microcontrollers has been based on the MC68HC705J1A, J2A and K1 series (mainly because that's what I have the development tools for). (...) (25 years ago, 30-May-01, to lugnet.robotics)
|
| |
 | | Re: Custom Firmware, IR Problems, and Dead RCXs (long)
|
|
(...) Oops. I just assumed that the RMS vs Peak value of an AC transformer and the subsequent consequences for the tower were so obvious that anyone with an electronics background would have pointed it out, and since you didn't, I figured you must (...) (25 years ago, 30-May-01, to lugnet.robotics)
|
| |
 | | Re: IR Tower Use
|
|
(...) The only IrCOMM I know of is part of the IrDA standard. It provides something that looks just like a typical serial port to the application, but underneath is layered on top of IrLAP (packet based link level prototocol for IrDA). This means (...) (25 years ago, 30-May-01, to lugnet.robotics.rcx, lugnet.robotics, lugnet.off-topic.geek)
|