The press room at www.legomindstorms.com has some new pictures of the two new kits due out this year. From these pictures, it's clear that the "Scout" unit - in the Robotics Discovery Kit - is very similar to the RCX; it has only 2 inputs, and (...) (28 years ago, 24-Apr-99, to lugnet.robotics)
 
  Reading sensors at equal intervals.
 
Is it possible (with the standard firmware) to read the RCX sensors (actually, ideally, to run any old subroutine) at equal intervals, ie like every 100ms or something? (I assume it must be, otherwise you couldn't measure speed with the angle (...) (28 years ago, 24-Apr-99, to lugnet.robotics)
 
  Steer kit
 
I bought the Steering kit, 5295, and now can't envision how all of the pieces can be used. Does anyone have any examples they could share? -- Did you check the web site first?: (URL) (28 years ago, 24-Apr-99, to lugnet.robotics)
 
  Re: Steer kit
 
David Cuthill <lego-robotics@crynwr.com> wrote in message news:01BE8DCB.0A59FE...ome.com... (...) One of the models on this page shows some of those parts. Sorry that they are not closeup. (URL) (...) (28 years ago, 24-Apr-99, to lugnet.robotics)
 
  Re: IR test reports "Rubbish" when I run test.c
 
Test.c expects to see both short and long pulses of IR, and it tries to accept timings from any remote. It times the signals it receives and records the lengths of the shortest and longest pulse. It then uses the midpoint of these values as a (...) (28 years ago, 24-Apr-99, to lugnet.robotics.handyboard)
 
  Re: Reading sensors at equal intervals.
 
(...) By standard firmware, I assume you mean using the byte codes ala NQC or something similar. If you only want semi-precise timing, you can use the wait opcode to delay for approximately 100 ms between sensor samples. If you want something more (...) (28 years ago, 25-Apr-99, to lugnet.robotics)
 
  Re: Reading sensors at equal intervals.
 
(...) I though that the four "Timer()" values read out in 100ms increments only. Is there a way to get a 1ms timer with NQC? thanks, DLC (28 years ago, 25-Apr-99, to lugnet.robotics)
 
  Rom sensor read routine
 
In writing some sensor code yesterday/today (it's 6 am), I passed over the ROM sensor code at 14c0. The documentation has been put in the usual place. The rotation code is pretty simple: the expected state machine, with split points between the four (...) (28 years ago, 25-Apr-99, to lugnet.robotics.rcx.legos)
 
  Re: Reading sensors at equal intervals.
 
(...) You are right, the timer values as seen by the firmware are in 1/10ths of a second. I lost myself in H8-land, which has a 1 ms timer that gets divided down before being seen by the firmware. -Kekoa (28 years ago, 25-Apr-99, to lugnet.robotics)
 
  Re: pneumatic switch control
 
Dennis Clark wrote in message ... (...) dropped (...) See demonstartion of the principle: (URL) pneumatic control from menu Eric Brok Visit LEGO ON MY MIND: (URL) Control section: (URL) section: (URL) (28 years ago, 26-Apr-99, to lugnet.robotics)