 | | RE: SENSOR_READ doesn't return 0
|
| (...) John, Thanks a lot for this catch. Sounds a lot like the email I exchanged with Kekoa regarding power down mode and external stacks, but that's another story... Cheers, Ralph Hempel - P.Eng ---...--- Check out pbFORTH for LEGO Mindstorms at: (...) (28 years ago, 15-Apr-99, to lugnet.robotics.rcx.pbforth)
| | |  | | RE: Useful constants
|
| (...) <snipped constant descriptions> John, These constants are indeed useful, but would make the resulting srec file pretty big. I have tried to make a TCL script to allow a sort of macro substitution. You can always load the constants after the (...) (28 years ago, 15-Apr-99, to lugnet.robotics.rcx.pbforth)
| | |  | | RE: preventing IR tower shutdown
|
| (...) Usually a capacitor lives across the power lines, and introducing a wire would be a good way of drianing the battery, burning the wire and possibly yourself!!! DON'T DO THIS... Cheers, Ralph Hempel - P.Eng ---...--- Check out pbFORTH for LEGO (...) (28 years ago, 15-Apr-99, to lugnet.robotics)
| | |  | | RE: Ir transmission
|
| (...) Alas, I only used the firmware timers available as core RCX firmware calls. I can look through Kekoa's disassembly to see if there are higher resolution timers available ( I think the motor timers might be useful ) In general, NQC hooks in (...) (28 years ago, 15-Apr-99, to lugnet.robotics.rcx.pbforth)
| | |  | | Re: Novice group
|
| (...) Ditto that. When I first picked up my mindstorms, I tried following .robotics for a while, but it was just too much effort sifting through the greek to get to the stuff I could understand. James (URL)Steve (...) (28 years ago, 15-Apr-99, to lugnet.admin.general, lugnet.robotics)
| |