| | Re: General question on ldr and mpd files ... [DAT]
|
|
(...) I'd hope any program would use the filename supplied. So if you had an mpd like this ... ===...=== 0 FILE a.ldr 0 Main File 0 Name: a.ldr 1 1 0 0 0 1 0 0 0 1 0 0 0 1 b.ldr 1 1 0 0 0 1 0 0 0 1 0 0 0 1 c.dat 1 1 0 0 0 1 0 0 0 1 0 0 0 1 d 0 FILE (...) (23 years ago, 8-Mar-02, to lugnet.cad)
|
|
| | General question on ldr and mpd files ...
|
|
We agreed on having the ldr extension in the future. But there is one point which is not clear for me: Normaly there should be *.dat entries inside a mpd file. Will older software work if I change the extension inside the mpd files? I would like to (...) (23 years ago, 8-Mar-02, to lugnet.cad)
|
|
| | Forestman Cap
|
|
I think I saw somewhere that the Forestman Cap was done - but I don't have it in my ldraw parts library and I can't find the dat file online. Help please? (23 years ago, 8-Mar-02, to lugnet.cad)
|
|
| | Re: LDraw.org MOTM/SOTM voting for March is open
|
|
Your R/W Complexity model looks very interesting. Was there some automated tools at work to generate it? (I award bonus points when voting for good use of tools). I've often thought of doing a tool that starts with a big cube of 1x1 plates and (...) (23 years ago, 8-Mar-02, to lugnet.cad)
|
|
| | Re: MOC's for the SFSC
|
|
(...) optional lines, which is why the antennae are near-invisible and the buffer ends aren't outlined. XFUT: lugnet.cad -- Tony Hafner www.hafhead.com (23 years ago, 8-Mar-02, to lugnet.trains, lugnet.cad)
|
|
| | 10020 (erm... 4 of 3) [DAT]
|
|
black train wheels 2 (change 2878.dat into this one) 0 Train Wheels 2 with black wheels 0 ROTATION CENTER 0 0 0 1 "Custom" 0 ROTATION CONFIG 0 0 1 16 20 20 20 1 0 0 0 -1 0 0 0 1 stud3.dat 1 16 0 20 20 1 0 0 0 -1 0 0 0 1 stud3.dat 1 16 -20 20 20 1 0 (...) (23 years ago, 8-Mar-02, to lugnet.cad.dat.models.sets)
|
|
| | 10020 (3 of 3) [DAT]
|
|
window (by thomas burger) 0 Windscreen 2 x 6 x 2 with Dual Windows 0 Author: thomas burger 0 unofficial LCAD element 2 1 40 8 0 0 8 0 2 24 40 8 -20 -20 8 -20 2 24 40 0 -20 -20 0 -20 4 16 40 0 -20 -20 0 -20 40 8 -20 -20 8 -20 2 2 -16 8 -16 40 8 -16 2 (...) (23 years ago, 8-Mar-02, to lugnet.cad.dat.models.sets)
|
|
| | 10020 (2 of 3) [DAT]
|
|
mock-up window 0 Panel 1 x 2 x 2 with round window (mock-up) 1 47 0 44 0 1 0 0 0 -1 0 0 0 1 stud3.dat 1 47 0 48 0 16 0 0 0 -4 0 0 0 6 box5.dat 4 47 20 48 10 16 48 6 -16 48 6 -20 48 10 4 47 -20 48 10 -16 48 6 -16 48 -6 -20 48 -10 4 47 -20 48 -10 -16 (...) (23 years ago, 8-Mar-02, to lugnet.cad.dat.models.sets)
|
|
| | 10020 (1 of 3) [DAT]
|
|
you need the next 2 files too! 0 FILE 10020.dat 0 10020 Sante Fe Super Chief 0 Name: 10020.dat 0 Author: jeroendehaan@mac.com 0 Official Model 0 ROTATION CENTER 0 0 0 1 "Custom" 0 ROTATION CONFIG 0 0 1 4 0 0 0 0 0 -1 0 1 0 1 0 0 4093.DAT 0 STEP 1 14 (...) (23 years ago, 8-Mar-02, to lugnet.cad.dat.models.sets)
|
|
| | Re: BFC and Primitives
|
|
(...) This was an issue during the BFC Thread Wars. We figured there were basically two ways to resolve the issue: 1. Make two versions of each primitive, an "outer facing" and an "inner facing". Each BFC'ed part file would need to use the correct (...) (23 years ago, 8-Mar-02, to lugnet.cad.dev.org.ldraw)
|