To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.technicOpen lugnet.technic in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Technic / 4211
4210  |  4212
Subject: 
Re: Guide to Control Lab
Newsgroups: 
lugnet.dacta, lugnet.technic, lugnet.robotics.rcx.robolab
Date: 
Thu, 8 Mar 2001 09:15:43 GMT
Viewed: 
294 times
  
"Lars Gertsen" <lars.gertsen@mail.tele.dk> wrote in message
news:3AA73386.14FEDBA0@mail.tele.dk...
Hello,

I have just bought a used Dacta control lab and I use it via
an ActiveX that I found on the net. However there are some
small details that I would like get cleared out.

1: What is the difference between the yellow and blue input connectors?

yellow=used for yellow sensors(touch, temperatur), sensors needs no power to
work.
blue=used for light and angle sensors, these sensors needs power to work.

2: What is the stop button for?

Turns power off for all output channels.

3: How can/should the on connector be used

If Control Lab is connected to the outlet, this connector is allways
powered. Used to test lamps and also to provide power to stuff that needs to
be powered constantly..

4: Is there any difference between the 8 output connectors.

Nope

5: Can I use an Mindstorms Light Sensor on the control lab?

Yes, see 1.

/Joakim



Message is in Reply To:
  Guide to Control Lab
 
Hello, I have just bought a used Dacta control lab and I use it via an ActiveX that I found on the net. However there are some small details that I would like get cleared out. 1: What is the difference between the yellow and blue input connectors? (...) (24 years ago, 8-Mar-01, to lugnet.dacta, lugnet.technic, lugnet.robotics.rcx.robolab)

8 Messages in This Thread:




Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

Custom Search

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR