  Re: Can Robolab stop the RCX switching off?
 
(...) Looks like there is a 255 minute powerdown time limit using ROBOLAB's Administrator. You can type in a higher number but the program reverts to 255. There's also the ROBOLAB program function "Set RCX Powerdown Time." Whether or not this obeys (...) (21 years ago, 2-May-04, to lugnet.robotics.rcx.robolab)
 
  Re: Can Robolab stop the RCX switching off?
 
(...) Entering a value of 0 is the trick to disabling the powerdown. (21 years ago, 2-May-04, to lugnet.robotics.rcx.robolab)
 
  Re: Can Robolab stop the RCX switching off?
 
(...) I know nothing about Robolab, but you might wanna try setting this value to 0. ROSCO (21 years ago, 2-May-04, to lugnet.robotics.rcx.robolab)
 
  Re: Can Robolab stop the RCX switching off?
 
(...) This *trick* is in fact documented on page 13 of the "Getting Started" Teacher's Guide for ROBOLAB Software where it says "A setting of 0 means the RCX always stays on". The sematics is likely to cause confusion because earlier on it says (...) (21 years ago, 4-May-04, to lugnet.robotics.rcx.robolab)