In lugnet.robotics.rcx.robolab, Charles Tomkins wrote:
> Hi,I would like to stop the RCX switching off after 30 mins can this be done
> using Robolab? I have the standard Mindstorms software and cannot see a way to
> do it. [the sprog and I are making 'burglar' alarms and surprises for each
> other] He is only 6 so NQC et al.could be a bit daunting.
> Could I alter anything in the setup of the std mindstorms software to do this?
> Thanks
> Chas
Looks like there is a 255 minute powerdown time limit using ROBOLAB's
Administrator. You can type in a higher number but the program reverts to 255.
There's also the ROBOLAB program function "Set RCX Powerdown Time." Whether or
not this obeys the same 255 minute limit or not, I cannot tell. I was able to
enter 10080 minutes (one week) and the program downloaded but whether or not it
would work is another matter. PBPowerDownTime (0xB1) is the LASM command to
handle the powerdown time. The documentation mentions no upper limit. You can
access LASM via ROBOLAB and you could create your own .vi icon, and call it
'poweroff' for your youngster.
Mitch Lichtenberg
|
|
Message has 2 Replies:
Message is in Reply To:
| | Can Robolab stop the RCX switching off?
|
| Hi,I would like to stop the RCX switching off after 30 mins can this be done using Robolab? I have the standard Mindstorms software and cannot see a way to do it. [the sprog and I are making 'burglar' alarms and surprises for each other] He is only (...) (21 years ago, 2-May-04, to lugnet.robotics.rcx.robolab)
|
5 Messages in This Thread:
- Entire Thread on One Page:
- Nested:
All | Brief | Compact | Dots
Linear:
All | Brief | Compact
This Message and its Replies on One Page:
- Nested:
All | Brief | Compact | Dots
Linear:
All | Brief | Compact
|
|
|
|