  pbForth vs RCX 1.0
 
Hi, Is pbForth fully compatible with RCX 1.0? Can RCX 2.0 communicate with RCX 1.0 in pbForth (using IR ports)? Thanks Mario (22 years ago, 26-Jun-02, to lugnet.robotics.rcx.pbforth)
 
  Re: pbForth vs RCX 1.0
 
"Mario Beaulieu" <mariobeaulieu@videotron.ca> writes... (...) Yes. I run pbForth on RCX 1.0, 1.5 and 2.0. No differences. (...) No, to my knowledge. In pbForth the IR port is entirely devoted to communication between the brick and the terminal. (...) (22 years ago, 27-Jun-02, to lugnet.robotics.rcx.pbforth)
 
  Re: pbForth vs RCX 1.0
 
Thanks, Just to make sure, let's take an example. Let's say that I have two RCX, named A and B. What if the program in RCX B is waiting for a character on the instruction KEY and RCX A sends a character, let's say '5' (ASCII 52) with 52 EMIT ? That (...) (22 years ago, 27-Jun-02, to lugnet.robotics.rcx.pbforth)
 
  RE: pbForth vs RCX 1.0
 
(...) What you describe would work exactly. Normally, the "outer interpreter" of pbForth waits for input using "KEY" - which of course is just a char from the IR. You can make a special word that waits for anything you like... Cheers, Ralph (22 years ago, 30-Jun-02, to lugnet.robotics.rcx.pbforth)