  Re: Aborting from ISR
 
Hi, (...) Yup, that does what I want, although I can't remember enough about forth internals to work out why it works. But it does seem to depend on the return stack having a particular structure, so I do wonder - what happens if the interrupt (...) (22 years ago, 20-Jul-02, to lugnet.robotics.rcx.pbforth)
 
  RE: Aborting from ISR
 
(...) Alex, I'll have a good look at this and then post an article. I have a funny feeling you're doing it the hard way, but that's because I know the insides of the patient better than you do - I am Dr Frankenforth after all! Oh, and sorry for the (...) (22 years ago, 17-Jul-02, to lugnet.robotics.rcx.pbforth)
 
  RE: Lazy newbieish question
 
(...) Matt, I see this all the time when I teach embedded C programming to desktop guys - it's an objectification of things at the wrong level. Maybe you could consider this: (setup-light-sensor 'PORT2) which expands to 3 1 SENSOR_TYPE 128 1 (...) (22 years ago, 17-Jul-02, to lugnet.robotics.rcx.pbforth)
 
  Lazy newbieish question
 
If I wasn't in a hurry with so many things to do in the next two days, I would figure this out for myself. My apologies for such a simple question. We're wrapping a lot sensor input stuff at a higher level of abstraction than the raw pbForth words. (...) (22 years ago, 17-Jul-02, to lugnet.robotics.rcx.pbforth)
 
  Re: Aborting from ISR
 
It works! (after countless crashes and firmwire reloads that is ... :) By modifying the saved Instruction Pointer to point to a memory area which in turn contains the address of an "abort word", on the next execution of a word (either inside a (...) (22 years ago, 16-Jul-02, to lugnet.robotics.rcx.pbforth)
 
  Re: Breaking from infinite loops
 
(...) Hi, if you just want to stop your "own" program use the Forth word ABORT or ABORT" : TEST 1000 0 DO \ do something run-button-down? ABORT" Aborted by user!" LOOP ; or if you want what looks like a "reset" use COLD: run-button-down? IF (...) (22 years ago, 16-Jul-02, to lugnet.robotics.rcx.pbforth)
 
  Re: Aborting from ISR
 
Ah I see... intriguing idea :) Rereading your original post it should have been quite clear what you wanted. Unfortunately (as far as I know) Mario is right, there doesn't seem to be a clean solution other than manipulating the return stack. I've (...) (22 years ago, 16-Jul-02, to lugnet.robotics.rcx.pbforth)
 
  Breaking from infinite loops
 
This feels vaguely similar to a question just recently posed, almost. I need a way to get out of a user program that intentionally defines an infinite loop. My best attempt so far at an exit word : exit POWER_OFF LCD_4TH LCD_REFRESH ; in the context (...) (22 years ago, 16-Jul-02, to lugnet.robotics.rcx.pbforth)
 
  Re: Aborting from ISR
 
(...) I see. Tired of re-booting hey? :o)) There's no way already available that I know of. I think that Mr. Hempel is looking into this. Maybe if we play with the return stack... (...) The way Forth works is that it is running the program. If you (...) (22 years ago, 15-Jul-02, to lugnet.robotics.rcx.pbforth)
 
  Re: Light sensor question
 
Hi Matt, I'll try to help. :o) First, you have to specify the type of sensor that is hooked on the port. You do that with: type port SENSOR_TYPE Let me know if you need to know the different values for 'type'. 3 is a light sensor. Ports are numbered (...) (22 years ago, 15-Jul-02, to lugnet.robotics.rcx.pbforth)