Subject: 
Re: Power Down for RCX
Newsgroups: 
lugnet.robotics.rcx.nqc
Date: 
Mon, 29 Jan 2001 07:23:18 GMT
Viewed: 
2075 times
  
Chris Hood wrote:

I know that in the diagnostics window for the RCX Control Center you can set
the "Power Down" time, this sends a message to the RCX about how long to
wait idle before power down. I would like to know the command (message) to
send to the RCX to make it power down "now" if that is a possibility for NQC
and the RCX.

nqc -sleep now  shuts off an RCX.

SetSleepTime(0);

Sets it from in NQC. Change 0 to whatever you want, in minutes for the shutdown.

Dean
--
Coin-Op's For Sale!: http://www.akasa.bc.ca/tfm/coin-op.html
Dean's Lego Workshop: http://www.akasa.bc.ca/tfm/lego_wr.html
Vancouver Lego Club: http://www.akasa.bc.ca/vlc



Message is in Reply To:
  Power Down for RCX
 
I know that in the diagnostics window for the RCX Control Center you can set the "Power Down" time, this sends a message to the RCX about how long to wait idle before power down. I would like to know the command (message) to send to the RCX to make (...) (24 years ago, 29-Jan-01, to lugnet.robotics.rcx.nqc)