Re: Possible bug in firm0328 or NQC 2.2
Newsgroups: 
lugnet.robotics.rcx.nqc
Date: 
Tue, 16 Jan 2001 11:14:01 GMT
Viewed: 
2409 times
  
"Dave Baum" <dbaum@spambgoneenteract.com> ha scritto:
You've got the args to OnFor() backwards.  It should be

OnFor(OUT_A + OUT_C, 30);

I feel totally stupid, first thing I should have checked.

Thanks Dave.

Mario



Message is in Reply To:
  Re: Possible bug in firm0328 or NQC 2.2
 
(...) You've got the args to OnFor() backwards. It should be OnFor(OUT_A + OUT_C, 30); If your original source had the args in the correct order, email it to me and I'll check the assembly listings to see what code is actually being generated. (...) (24 years ago, 13-Jan-01, to lugnet.robotics.rcx.nqc)