  Re: time sampling under the rcx standard OS
 
(...) Francois, I think you should be able to get much faster sampling. I can easily get 10-20 Hz, and others have claimed to get down to 3 ms. Whether it can be done at a constant rate, I'm not sure, and think it probably depends on what else is in (...) (19 years ago, 17-Sep-05, to lugnet.robotics.rcx.nqc)
 
  RE: time sampling under the rcx standard OS
 
Here are some comments on how to improve your code for real-time performance. 1. Move the "SetUserDisplay" out of the loop and put it just before the loop. 2. I think the "OnFwd" macro is actually two instructions: "Fwd" and then "On". Replace this (...) (19 years ago, 17-Sep-05, to lugnet.robotics.rcx.nqc)
 
  Re: time sampling under the rcx standard OS
 
Thank you Matt, the RCX loops much faster with your advices : about 10 loops per second. But as this frequency depends on the calculations included in the loop, I’m afraid this will not be enough. So I tried to download (URL) but it just appears as (...) (19 years ago, 18-Sep-05, to lugnet.robotics.rcx.nqc)
 
  Re: time sampling under the rcx standard OS
 
Thank you Dick, for advicing me to switch to the faster firmware, I’m sure I need both a 1-millisecond basic clock, and the 128 power level capability. So I tried to download it from (URL) but it just appears as a text file, which I don’t know how (...) (19 years ago, 18-Sep-05, to lugnet.robotics.rcx.nqc)