  Re: disable LNP
 
(...) Sorry, nothing has made it to an official release. I think Joseph Woolley has some code where he reduced the sample rate to 1KHz (I think). You might try contacting him about it. Mark (21 years ago, 11-Oct-03, to lugnet.robotics.rcx.legos)
 
  Re: disable LNP
 
(...) Mark is correct: I made the following two changes which will cause the sensors to be polled at 1KHz: in systime.c; added "bset #0x5,@_AD_CSR:8"; extern void clock_handler(void); ... sys_nohigh: mov.w #0x5a06,r6 ; reset wd timer to 6 mov.w (...) (21 years ago, 12-Oct-03, to lugnet.robotics.rcx.legos)
 
  RE: disable LNP
 
(...) Doesn't the H8/300 have a mode where you can scan up to 4 channels at once? Ralph (21 years ago, 12-Oct-03, to lugnet.robotics.rcx.legos)
 
  Re: disable LNP
 
(...) I actually had already tried this, but couldn't get it to work. Turns out I was having a problem with generating the linker file (genlds). Once I resolved that, it works GREAT! As you may expect, the processor intensive program I've written, (...) (21 years ago, 13-Oct-03, to lugnet.robotics.rcx.legos)