Subject: 
Re: Any substitute to the default lego serial cable!
Newsgroups: 
lugnet.robotics.rcx.java
Date: 
Wed, 24 Jul 2002 15:21:20 GMT
Viewed: 
4425 times
  
The cable is wired as a null modem cable (see
http://graphics.stanford.edu/~kekoa/rcx/). If that's what you have, then it
should work.

A couple of other questions:

1. When you try to download the firmware does the green light on the tower
come on?
2. Have you set RCXTTY to the correct value (it defaults to COM1)?
3. What error does lejosfirmdl report?
4. What error doe sit report if you use the -v flag?
5. Are you using the -f flag? If so try it without that flag.
4. Have you put the battery in the tower?

Sorry if these are dumb questions, but you never know ;-)

In lugnet.robotics.rcx.java, Laurence K.W. Yip writes:
Hi, all!

I've just bought and got a IR serial tower from bricklink but I haven't
a default lego serial cable. Originally, I think ordinary RS-232 DB-9F
to DB-9F cable can be used instead, but I fail to do the firmware
downloading under Win98 RIS UI interface. Can anyone tell me is  it
necessary to use the default LEGO serial cable without any
substitiution?

Rgds,

Laurence



Message has 1 Reply:
  Re: Any substitute to the default lego serial cable!
 
Hi! Paul, | |Thanks for your help first. I didnt' test it using lejos! I just used |the default LEGO RIS UI in win98 to try to download the lego default firmware |to RCX brick! |When the dialog box under the hardware setting option informed me the (...) (22 years ago, 24-Jul-02, to lugnet.robotics.rcx.java)

Message is in Reply To:
  Any substitute to the default lego serial cable!
 
Hi, all! I've just bought and got a IR serial tower from bricklink but I haven't a default lego serial cable. Originally, I think ordinary RS-232 DB-9F to DB-9F cable can be used instead, but I fail to do the firmware downloading under Win98 RIS UI (...) (22 years ago, 24-Jul-02, to lugnet.robotics.rcx.java)

5 Messages in This Thread:

Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact

This Message and its Replies on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

Custom Search

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR