  Re: Difference in motorspeed when activating lightsensor!
 
Hello, (...) Ok, I feel like an idiot now; I cannot reproduce the result! I did it this morning, but altered the program afterwards! But when I try now, nothing happens! As I recall it, it was the same program with the light sensor actived all the (...) (23 years ago, 9-Sep-01, to lugnet.robotics.rcx.java)
 
  Re: Difference in motorspeed when activating lightsensor!
 
(...) The higher the power level the harder the stop. But the power level before stop() is not used, it always uses power level 7, and you can set it lower only afterwords. (I think that ought to change.) Jürgen (23 years ago, 9-Sep-01, to lugnet.robotics.rcx.java)