To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcxOpen lugnet.robotics.rcx in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / 79
78  |  80
Subject: 
Re: RCX Currnet Rating?: And info on Internals??
Newsgroups: 
lugnet.robotics.rcx
Date: 
Sun, 12 Sep 1999 07:22:06 GMT
Viewed: 
1306 times
  
Terry King <tking@together.net> wrote:
I'm still not clear on exactly what the RCX enternal-power
input will accept. Can anyone tell us what the internals
really are??

If I view the RCX power connector closely, I read:

9-12V~    (nine dash one two Vee tilde)

I would interpret that to mean:
"Nine to Twelve Volts AC"

It is commonly believed that the RCX contains a full rectifier, so if you
supplied AC, that would work, but more importantly, if you supplied either
polarity of DC, that would work also.  The conversion to AC also requires a
sufficiently large capacitance, and if you take a peek into your RCX (or
mine, at http://graphics.stanford.edu/~kekoa/rcx/), you will find that the
RCX contains enough capacitors to safely power the entire state of New York
well into Y2K.  The general consensus is that the label on the input is
truly correct.  It reads as you interpreted it.

Also, will it 'accept' 9 to 12 volts DC because of
internal diodes??

Yes.

I understand many of you are using "Wall Wart"
supplies that put out 9 volts DC and they work OK.
Is that true??

They do not work okay, they work more than okay.  That is, unless you want
to build the Torbot.  Standard disclaimer applies though.  Do not blame me
if you break something by listening to my meaningless ramblings about what
may or may not be inside your RCX.

-Kekoa



Message has 1 Reply:
  Re: RCX Currnet Rating?: And info on Internals??
 
Kekoa, Many Thanks for your tireless digging. I have seen a lot of very interesting stuff you have unearthed. I think that more is often learned about Engineering by 'Reverse Engineering' than 'forward'! Years ago I used to get tons of old IBM (...) (25 years ago, 12-Sep-99, to lugnet.robotics.rcx)

Message is in Reply To:
  Re: RCX Currnet Rating?: And info on Internals??
 
I'm still not clear on exactly what the RCX enternal-power input will accept. Can anyone tell us what the internals really are?? If I view the RCX power connector closely, I read: 9-12V~ (nine dash one two Vee tilde) I would interpret that to mean: (...) (25 years ago, 12-Sep-99, to lugnet.robotics.rcx)

9 Messages in This Thread:



Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact

This Message and its Replies on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    