Knowing the resistor inside the RCX is 10 kOhm, you should use a different
resistor for each switch,
the first resistor should be 10 kOhm, the second 30 kOhm, third 70 kOhm, fourth
150 kOhm, this will divide the 5V range in nearly evenly spaced sections


Ciaran Jessup wrote:

Hi, has anyone had any joy combining the input from several micro-switches
into one RCX input, I've built a simple multiplexor for three lego touch
sensors, but now I need four!! .. I know this can be done by adjusting my
current design, except I can't afford to wait for the three weeks it will
take for me to receive a new Lego Touch sensor from dacta, however I have
lots of micro-switches lying around.

I imagine its easier to combine many micro switches as they are just simply
on off switches so the boundaries are much easier to compute...

Thank you very much for any help you can provide

- Ciaran

Stef Mientki



Message is in Reply To:
  Micro-Switches, Mux
 
Hi, has anyone had any joy combining the input from several micro-switches into one RCX input, I've built a simple multiplexor for three lego touch sensors, but now I need four!! .. I know this can be done by adjusting my current design, except I (...) (24 years ago, 26-Feb-01, to lugnet.robotics.rcx)

5 Messages in This Thread:



Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

Custom Search

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR