To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcxOpen lugnet.robotics.rcx in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / *4960 (-5)
  transfer data failed
 
Hi there, I use legOS 0.2.4 under Linux and tried (after a few weeks) to download the firmware and get always the follwing error: firmdl3/firmdl: transfer data failed Batteries are brand new, tower was set to short and long dist. nothing helped ... (...) (23 years ago, 6-Aug-01, to lugnet.robotics.rcx.legos)
 
  RE: SetWatch() only accepts constants
 
Instead of sending ByteCodes from the PC and getting the RCX to interpret them, you can construct and send the SetWatch() OpCode plus the correct "constant" time and send it through Spirit.OCX (or directly, depending of the platform). (...) (23 years ago, 7-Aug-01, to lugnet.robotics.rcx.nqc)
 
  SetWatch() only accepts constants
 
I just wrote a task and function that cause the RCX to receive data from the PC and then set the time on the RCX using SetWatch(). Unfortunately, I didn't realize that SetWatch() only accepts constants. NQC complained when integer variables were (...) (23 years ago, 7-Aug-01, to lugnet.robotics.rcx.nqc)
 
  Re: Rechargeable Batteries
 
(...) Roger, I believe the low voltage is more important. A side issue is the battery indicator that you access through NQC (or Robolab) set up in a scale of 0-9 volts. Fully charged alkalines are 9+ and discharged ones are 6 volts. With NiMH full (...) (23 years ago, 6-Aug-01, to lugnet.robotics.rcx)
 
  Re: Rechargeable Batteries
 
(...) They have a higher voltage of about 3V and are tricky to charge, if you don't do it right they have a tendency to explode. I've never seen standalone cells and charger. Jürgen (23 years ago, 6-Aug-01, to lugnet.robotics.rcx)


Next Page:  5 more | 10 more | 20 more

Redisplay Messages:  All | Compact

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR