Subject:
|
Re: Polaroid Sonar Device fried!!!!
|
Newsgroups:
|
lugnet.robotics.handyboard
|
Date:
|
Sun, 28 Mar 1999 17:48:16 GMT
|
Original-From:
|
Will Bain <willbain@cs.umt.^StopSpammers^edu>
|
Viewed:
|
1069 times
|
| |
| |
SCOTT SHERMAN wrote:
> The C3279 chip ("Q1") on my sonar device fried. I checked the expansion
> board and it is assembled correctly. I am not sure why it would fry. I
> added the 0.1uF electrolytic capacitor to C7 position as stated in the
> sonar.html site and suggeted by an email. Does anyone have any idea why
> this would happen?
The most common causes would probably be: (1) Not having a transducer hooked up when the ping is initiated; (2) Having the flat flex cable plugged in backwards (you can't trust the stripe to be on the correct side! Make sure pin 1 goes to ground and pin 9 goes to V+); and (3) Too high a voltage to the sonar module (perhaps it's not being regulated properly). Of course, chips sometimes just die for no apparent reason. Good luck!
-- Will
, ,
, ,
__@_/ \_@__ |/
| /__, o @_/
)\ ) ( \ (\/\\,
~~~~~~~~~ ' ` ~~~~~~~~~~~ ` ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Wendy Parson, I don't want to achieve immortality through my work.
Will Bain, I want to achieve it through not dying.
& Tatoosh --Woody Allen
|
|
Message is in Reply To:
| | Polaroid Sonar Device fried!!!!
|
| The C3279 chip ("Q1") on my sonar device fried. I checked the expansion board and it is assembled correctly. I am not sure why it would fry. I added the 0.1uF electrolytic capacitor to C7 position as stated in the sonar.html site and suggeted by an (...) (26 years ago, 28-Mar-99, to lugnet.robotics.handyboard)
|