    Ooops. —Michael Chang
   Help! I accidently plugged a network rj11 cable between my HB and the serial interface board. It seems that I released the smoke genie from R 11. I have replaced the resistor and the MAX 232 but I'm not getting the board to sync. Is there anything (...) (27 years ago, 16-Nov-97, to lugnet.robotics.handyboard)
   
        Re: Ooops. —Fred G. Martin
   It's unlikely you killed the MCU, there are 1k resistors in series with the RxD and TxD lines. Go to the assembly manual, and run through the series of tests that verify proper operation of the Interface/Charger Board. (URL) your message you said: (...) (27 years ago, 17-Nov-97, to lugnet.robotics.handyboard)
 