In article <4.2.2.19991215124731.00ce3d00@mail.connect.net>, Joel Shafer
<joel@connect.net> wrote:
> So if you need a 1, 1.5 & 2ms pulse for controlling a servo and you said
> the low setting in NQC = a 1ms pulse, are there other matching motor speed
> settings to get a 1.5 or 2ms pulse?
The pulses are 1ms, 2ms, 3ms....7ms, 8ms. The 8ms case is sort of a
degenerate case since the period itself is 8ms, so an 8ms pulse winds up
being continuous power.
Dave Baum
--
reply to: dbaum at enteract dot com
|
|
Message is in Reply To:
| | Re: RCX Output
|
| So if you need a 1, 1.5 & 2ms pulse for controlling a servo and you said the low setting in NQC = a 1ms pulse, are there other matching motor speed settings to get a 1.5 or 2ms pulse? (...) Joel Shafer joel@connect.net (25 years ago, 15-Dec-99, to lugnet.robotics)
|