Errm wrong message reply?
Gordon Elliott wrote:
> Don't forget that the microcontroller probably puts out pulses to control
> the motor's power level. So the pulses one would see in normal operation
> have little to do with the pulses of the DC motor comutation. A common
> technique to control power level would be "pulse width modulation," and I
> see a mention of "ticks" somewhere in this discussion. That would make
> sense, as the microcontroller might turn motor on N ticks out of 8, for
> example, to give 8 power levels (and off). (If that's 8 total, it might be 0
> through 7 of 8 time slots. At least one note
> http://graphics.stanford.edu/~kekoa/rcx/ says that other power levels would
> be ignored, so 7 and 8 might not differ as all treated as "7" -- someone
> with direct knowledge could comment.
>
>
> -- Gordon Elliott
>
>
|
|