| | Gp2D12 Distance Sensor interface to RCX
|
|
Mindsensors is pleased to announce the New relies of GP2D12 sensor interface to RCX. This Sensor Interface is mainly based on Philos Concept but with little different Ckt and very compact. For more details visit Mindsensors Robotics web page at (...) (23 years ago, 18-Oct-01, to lugnet.robotics)
|
|
| | Re: Gp2D12 Distance Sensor interface to RCX
|
|
The web site you are trying to access has exceeded its allocated data transfer. Visit our help area for more information. (...) (23 years ago, 18-Oct-01, to lugnet.robotics)
|
|
| | Re: Gp2D12 Distance Sensor interface to RCX
|
|
Hello Nitin, Nice job ! Mechanical design is especially neat, electronics one probably too but I have trouble reading the schematics, could you mail me a larger one ? As far as I can see you use a 1 Farad Supercap ? interesting... much more freedom (...) (23 years ago, 19-Oct-01, to lugnet.robotics)
|
|
| | Re: Gp2D12 Distance Sensor interface to RCX
|
|
Very nice. Now is someone would just build my ideal infrared sensor mux for me I would be all set. Features: 1 - 7 GP2D12s Random Access Quick Response External Power A way for the RCX to monitor power small size Anyone interested? (...) (23 years ago, 19-Oct-01, to lugnet.robotics)
|
|
| | Re: Gp2D12 Distance Sensor interface to RCX
|
|
(...) Do you want all of the sensors to be active at the same time, or do you want to be able to activate/disable them? If they are all simultaneously active, they draw a lot of power and there is a greater chance of interference. Allowing some to (...) (23 years ago, 19-Oct-01, to lugnet.robotics)
|
|
| | Re: Gp2D12 Distance Sensor interface to RCX
|
|
They don't need to be all active, just appear that way. I am assuming a dip switch to permanantly deactivate unused, ports. Software control of connected ones would be nice. Usage would go like this: 7 Global variables, a thread checks them on a (...) (23 years ago, 19-Oct-01, to lugnet.robotics)
|
|
| | Re: Gp2D12 Distance Sensor interface to RCX
|
|
(...) Sounds like you have a fairly good idea of how you want to use it, and it all makes sense. The hardware can be simplified quite a bit if this is the typical usage pattern, though. (...) Since the RCX is already storing the values for use by (...) (23 years ago, 19-Oct-01, to lugnet.robotics)
|
|
| | Re: Gp2D12 Distance Sensor interface to RCX
|
|
about 3 times a second is fine, for most applications. A continous power option would be handy sometimes. If I remember right the 50ms, is the charge time required for the cap to get to power to activate the gp2d12, not for it to actually startup (...) (23 years ago, 19-Oct-01, to lugnet.robotics)
|
|
| | Re: Gp2D12 Distance Sensor interface to RCX
|
|
The 50 ms period _IS_ the startup time of the GP2D12 itself, and the time interval between two distance measurements. See oscilloscope trace (top of page): www.philohome.com/se.../scope.htm Philo (...) (23 years ago, 20-Oct-01, to lugnet.robotics)
|
|
| | Re: Gp2D12 Distance Sensor interface to RCX
|
|
(...) Just for your remembrance, i build something like that based on the schematics of Michael Gasperi. Please have a look here : (URL) (23 years ago, 20-Oct-01, to lugnet.robotics)
|