In lugnet.robotics, Philippe Hurbain writes:
> The 50 ms period _IS_ the startup time of the GP2D12 itself, and the time
> interval between two distance measurements. See oscilloscope trace (top of
> page): www.philohome.com/sensors/scope.htm
>
> Philo
>
> > If I remember right the 50ms, is the charge time required for the cap to get
> > to power to activate the gp2d12, not for it to actually startup and take a
> > reading. Am I correct in that?
Just for your remembrance, i build something like that based on the
schematics of Michael Gasperi.
Please have a look here :
http://www.informatik.fh-hamburg.de/~lego/Projekte/projekte_englisch.html
Regards,
Rainer
|
|