| | Re: Distance sensor for RCX based on Sharp GP2D12
|
|
Rainer, Do I need another 4066? Can't I just use the fourth one in the current 4066? (...) (24 years ago, 23-Apr-01, to lugnet.robotics)
|
|
| | Re: Distance sensor for RCX based on Sharp GP2D12
|
|
Hi Steven, you need another 4066. The fourth bilateral switch is connected to ground. This provides (using the 2.2kOhm resistor) a reference value for the RCX. This values mark your start point. This makes it possible to know "where" you are with (...) (24 years ago, 23-Apr-01, to lugnet.robotics)
|
|
| | Re: Distance sensor for RCX based on Sharp GP2D12
|
|
Steven Nickle (to Rainer Balzerowski) asked: (...) Instead of a 4017 switching a 4066, why not use a 4518 controlling a 4051 analog multiplexer? That would keep the IC count the same, but allow you to manage 7 GP2D12's using the original strategy (...) (24 years ago, 1-May-01, to lugnet.robotics)
|
|
| | Re: Distance sensor for RCX based on Sharp GP2D12
|
|
Hi Steve, sounds good to me ! Try it and let us know, if it does work (why shouldn't it ?!?). Sad, but I don't own 15 (not even 7) Sharps. :( But, if changing the supply voltage (using a switch to chose between 5V from regulator (for sharps) or (...) (24 years ago, 2-May-01, to lugnet.robotics)
|