 | | Re: What about multiplexing sensors?
|
|
(...) MUX is short for 'multiplexer' -- it is essentially a multi-switch device that switches a single input (or output) to multiple outputs (inputs). It would allow you to have 8 sensors (for example) connected to one input port and you could (...) (28 years ago, 11-Nov-98, to lugnet.robotics)
|
| |
 | | Re: What about multiplexing sensors?
|
|
Okay...thanks. --Andy (28 years ago, 11-Nov-98, to lugnet.robotics)
|
| |
 | | Re: What about multiplexing sensors?
|
|
(...) Hang on - if you use all 3 outputs to control the MUX (which leaves me wondering why you'd bother - trees falling in forests and all that) you can get 24 inputs, even if you only treat each output as binary. More plausibly, you can use 2 (...) (28 years ago, 11-Nov-98, to lugnet.robotics)
|
| |
 | | Re: RCX Programming Questions and Sensor Ideas
|
|
In article <199811102221.OAA071...ford.EDU>, Kekoa Proudfoot <kekoa@Graphics.Stanford.EDU> quotes and writes (...) You are right, of course. (...) If it does I haven't found it. (28 years ago, 11-Nov-98, to lugnet.robotics)
|
| |
 | | RE: What about multiplexing sensors?
|
|
You should be able to have three or more on/off sensors share a single input port without multiplexing. Just use a different resistor for each, so that any combination of pressing the three sensors yields a unique value out of 8 possible. For (...) (28 years ago, 11-Nov-98, to lugnet.robotics)
|