| | Re: Power Function control with RCX and BrickOS
|
| (...) Okay, thanks. I can get 'Single output Mode' to work now. 'Single pin Mode' may be working too, but I'm not sure what to expect from it. I would expect setting either C1 or C2 would set them to 9V and run a motor forwards or backwards. Setting (...) (17 years ago, 26-Jan-08, to lugnet.general, lugnet.technic, lugnet.trains, lugnet.robotics, FTX)
| | | | Re: Power Functions infra-red RC protocol released!
|
| (...) I'd be very interested in that experiment (using a Hobby train RC on the PW Receiver) as well, but this does answer a number of questions for trains. For instance, tunnels and large layout out of line-of-sight on the RC should now be possible. (...) (17 years ago, 26-Jan-08, to lugnet.technic, lugnet.trains, lugnet.robotics)
| | | | Re: Power Functions infra-red RC protocol released!
|
| (...) Either single pin modes allow to set each output to 1 (9V) or 0 (0V). (...) See the drive datasheet: (URL) can reach 1A peak, continuous value is lower (500-600mA) especially if both outputs are heavily loaded at the same time. Philo (17 years ago, 26-Jan-08, to lugnet.technic, lugnet.trains, lugnet.robotics)
| | | | Re: Power Function control with RCX and BrickOS
|
| (...) Bob, I could not wait to get home from work to try this. I want to say thank you; your effort has saved me many countless hours. I loaded the Firmware, and the Program into a 1.0 RCX, and the brick worked flawlessly! On my 1.0 brick, I was (...) (17 years ago, 26-Jan-08, to lugnet.general, lugnet.technic, lugnet.trains, lugnet.robotics)
| | | | Re: Power Function control with RCX and BrickOS
|
| (...) The toggle bit is checked in Single output mode (the documentation is not quite right for this mode) and in both single pin modes. each message is sent 5 times you need to toggle the toggle bit in every message sent. 0 1 0 1 0 1 0 1 etc. bob (17 years ago, 25-Jan-08, to lugnet.general, lugnet.technic, lugnet.trains, lugnet.robotics, FTX)
| |