To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.roboticsOpen lugnet.robotics in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / *38340 (-10)
  Re: More than 1 integer in a data packet?
 
(...) I'm not a leJOS expert by any stretch of the imagination. But I think I can help. (...) That is not a correct understanding of the rcxcomm package API. The RCXOutputStream class, for example, which descends from java.io.OutputStream inherits (...) (22 years ago, 2-Oct-03, to lugnet.robotics.rcx.java)
 
  Re: Using .lsc files with RIS 1.5?
 
(...) I would recommend using BricxCC to edit/compile/download your .lsc file. I'm not sure what is in RCX2Def.h but if you post the .lsc contents (or email them to me) I'm sure I can figure out how to use the .lsc without needing the RCX2Def.h (...) (22 years ago, 2-Oct-03, to lugnet.robotics)
 
  Re: write files2
 
(...) Markus, I second Chris' request that you explain more fully what you are trying to do exactly. Why do you need your output formatted as result1;result2;result3..., for instance? John Hansen (22 years ago, 2-Oct-03, to lugnet.robotics.rcx.nqc)
 
  Re: write files2
 
(...) You probably do not want to use the datalog if you just want to get the latest lightsensor reading every two seconds. Here's a way to do it if you can use JavaScript and if you have BricxCC installed (since BricxCC implements an out-of-process (...) (22 years ago, 2-Oct-03, to lugnet.robotics.rcx.nqc)
 
  Re: write files2
 
(...) By "connected" do you mean always within range of the infrared tower? (...) How long do you need to do this? Do you need to access the text file while the robot is running, or do you only plan to use the data after the experiment is over? (...) (22 years ago, 2-Oct-03, to lugnet.robotics.rcx.nqc)
 
  thanks for your hints
 
Hi ! Thank you for your advices and tipps concerning my problem. I'm not quite sure, how I am going to replace the IR - interface, but I think I'll use a bluetooth - module or or just normal radio - communication instead of IR. I know, that this (...) (22 years ago, 2-Oct-03, to lugnet.robotics)
 
  Re: write files
 
(...) Of course. How silly of me to forget that NQC, the most influential piece of RCX software ever written, has built-in support for the datalog. I use NQC for the majority of my projects, and have found it to be the quickest way to develop RCX (...) (22 years ago, 1-Oct-03, to lugnet.robotics.rcx.nqc)
 
  Re: write files2
 
(...) btw: the results must be saved: e.g: log.txt consists: result1;result2;result3... (22 years ago, 1-Oct-03, to lugnet.robotics.rcx.nqc)
 
  write files2
 
thx for your answers. let me specify the problem better: the rcx is always connected with the PC. now i have a lightsensor and i want to save the results of the lightsensor every 2 seconds to my log.txt file ;) What is the best and easyiest way to (...) (22 years ago, 1-Oct-03, to lugnet.robotics.rcx.nqc)
 
  More than 1 integer in a data packet?
 
Hi there, Does anyone know if I can send more than 1 byte/integer per packet between the PC and RCX. From what I understand of the rcxcomm package API, one can only send an integer at a time. Also, the example supplied with the rcxcomm package only (...) (22 years ago, 1-Oct-03, to lugnet.robotics.rcx.java)


Next Page:  5 more | 10 more | 20 more

Redisplay Messages:  All | Compact

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR