  Re: Home-made One-way valve
 
(...) Alas it doesn't work that way at all. The air tanks will definitely not work with the old style pneumatics whatever way you try to incorporate them in (yep, I spent a good hour checking). Now as I understand it, the air tank is meant to store (...) (24 years ago, 18-Dec-01, to lugnet.robotics, lugnet.technic, lugnet.build)
 
  How to get interval of time
 
In NQC, I can use ClearTimer(0) and Timer(0) to get interval of time, how can I do it in legOS? I used t1 = sys_time, then t2 = sys_time, so interval = t2 - t1, is it correct? Zhengrong (24 years ago, 18-Dec-01, to lugnet.robotics.rcx.legos)
 
  Robot Controller 1.2b1
 
I've posted a new version of Robot Controller ---the ideal companion to NQC for Mac OS X users. This version fixes a couple of bugs. Download from: (URL) the way, has anyone tried it? It would be nice to get some feedback! Barney. (24 years ago, 17-Dec-01, to lugnet.robotics.rcx.nqc)
 
  Re: RCX remote control and the use of PICs
 
Hi Stef, A great project, well designed, and very well documented and presented. Thanks! I'll probably make one of these pretty soon. Nice work Michael (...) (24 years ago, 17-Dec-01, to lugnet.robotics, lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)
 
  RCX remote control and the use of PICs
 
hi All, Inspired by some applications of the 16F84 PIC, we came up with the idea to make a IR-module, which is capable of doing all the InfraRed tasks we could imagine with the RCX. Well it hasn't come so far, but we have build a RCX IR-remote (...) (24 years ago, 17-Dec-01, to lugnet.robotics, lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)
 
  Re: How to read the touch sensors on the Scout in NQC?
 
I was using my scout this past weekend as a coinbox detector to launch a mono rail. The touch sensors work exactly as Dave suggests. You can also just do the following: until(SENSOR_1); Waits until it's touched. until(!SENSOR_1); Waits until the (...) (24 years ago, 17-Dec-01, to lugnet.robotics.rcx.nqc, lugnet.robotics.scout)
 
  Re: Injection-Molding Factory
 
(...) I will try to answer your questions here: Andrew- ROBOLAB is a great program. NQC is also a great program. I have used them both. It depends on which you prefer. In my case, I do not use (say) C++ elsewhere and I find ROBOLAB easier to (...) (24 years ago, 17-Dec-01, to lugnet.robotics)
 
  Re: Shuting up the RCX
 
(...) Change the firmware. Maybe we should make this a selling point of Lejos :-) (at the moment it beep too, I think) Jürgen (24 years ago, 17-Dec-01, to lugnet.robotics.rcx)
 
  Re: How to read the touch sensors on the Scout in NQC?
 
(...) That is what I thought, but it will determine if the touch sensor is pressed. (...) Dunno, I'll try. Then again, if !=255 works... (...) If it were not for Perl I'd never write a line of code ^_^ (24 years ago, 17-Dec-01, to lugnet.robotics.rcx.nqc, lugnet.robotics.scout)
 
  Re: Home-made One-way valve
 
(...) Difficult to regulate though - as the same pump affects both. When the high pressure one is full & low pressure one needs pumping, it'll keep adding pressure to both (one outside, one inside). You'd have to have some kind of pressure release (...) (24 years ago, 17-Dec-01, to lugnet.robotics, lugnet.technic, lugnet.build)