| | Re: Power Function control with RCX and BrickOS Jason J Railton
| | | (...) I don't have BrickOS, but I have been playing with the protocols in NBC. I got the twin-motor PWM mode to work in tests, and the original 'Combo direct'. But I can't get 'Single output' or either of the 'Single pin' modes to work. Have you had (...) (17 years ago, 25-Jan-08, to lugnet.general, lugnet.technic, lugnet.trains, lugnet.robotics, FTX)
| | | | | | | | Re: Power Function control with RCX and BrickOS Bob Kojima
| | | | | (...) The toggle bit is checked in Single output mode (the documentation is not quite right for this mode) and in both single pin modes. each message is sent 5 times you need to toggle the toggle bit in every message sent. 0 1 0 1 0 1 0 1 etc. bob (17 years ago, 25-Jan-08, to lugnet.general, lugnet.technic, lugnet.trains, lugnet.robotics, FTX)
| | | | | | | | | | | | Re: Power Function control with RCX and BrickOS Jason J Railton
| | | | | (...) Okay, thanks. I can get 'Single output Mode' to work now. 'Single pin Mode' may be working too, but I'm not sure what to expect from it. I would expect setting either C1 or C2 would set them to 9V and run a motor forwards or backwards. Setting (...) (17 years ago, 26-Jan-08, to lugnet.general, lugnet.technic, lugnet.trains, lugnet.robotics, FTX)
| | | | | | | | | | | | Re: Power Function control with RCX and BrickOS Bob Kojima
| | | | | (...) i have not really spent a lot of time trying to figure these modes out. i was more concerned with getting the PWM to work correctly. i'm going to spend more time testing this and will let you know. bob (17 years ago, 26-Jan-08, to lugnet.general, lugnet.technic, lugnet.trains, lugnet.robotics, FTX)
| | | | | | |