To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.trainsOpen lugnet.trains in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Trains / 12842
12841  |  12843
Subject: 
Re: Some 9V questions of a 12V user
Newsgroups: 
lugnet.trains
Date: 
Sun, 5 Aug 2001 14:17:18 GMT
Viewed: 
416 times
  
"Ferdinand Geronimo" <fgw@dds.nl> wrote in message
news:GHLGzs.Bt2@lugnet.com...
Hello everybody,

I have been reading this newsgroup for quite some time, and have some
questions of my own now.

I use the 12V train system, which I think is still the best of all, but I • do
like the 9V Metroliner that is coming out. Because of this, I have decided • I
will start using the 9V system as well, independent of the 12V tracks.

My questions are however: in the 12V system, it is possible to make the
trains stop using signals. Power is always on the tracks, (independent of
the switches), only when the signal is Red, the power goes and the train
stops. This allows me to drive 3, 4 or even 5 trains on one piece of • track,
using the signals to prevent the trains having a collision. Does the 9V
system have anything like this? Is it possible to drive two trains on one
track, or do you need two separate tracks? Or do you use switches?


I was also a 12V fan at one time and ran into the same questions.  It is
very unfortunate that set 7860 signal light does not exist in the 9V system
that you can just pick from SAH.  Power to a line can only be cut off using
the points and are a DIY to hook up to a motor and polarity switch (no 7859,
7858 or 7863 stuff).  You can run more than one train but only one circuit
is getting the power.   If you have 12V set 7856 points, that is what you
will be dealing with in the 9V 4531 points with ability to cut power.  They
will do the job of a 7860 but without lights or something you may connect to
the transformer.  Many people on the group have ways of modifing 9V ones to
act like 7859 and 7858 and that is something you might look into.

Another question, the 12V transformer has three power supplies, one for
0-12V (train), one 12V~ (not used) and one 12V=. The last one can be used
for remote controls, and illumination. Does the 9V transformer also have • an
extra 9V= power supply in case I want to illuminate some buildings? Is • this
possible at all with 9V? I also liked it if I could build in lights in all
the houses and buildings, as well as in the trains.

The only way power goes out is through the 9V 2x2 conducting plate and wires
can set above or beneath.  I'd say the best action IMHO is to use Technic
polarity switches (sets like the 8480 space shuttle came with these or try
Pitsco).  Someone recently posted photos of such a setup (HELP out there! I
forgot who!) and it looked great!  It can provide you with the help you need
to give your lights and any non-train motors the power they need to function
and have trains running and turn whatever off or on.  Hope this helps.

Adrian


Thank you in advance,

FG





Message is in Reply To:
  Some 9V questions of a 12V user
 
Hello everybody, I have been reading this newsgroup for quite some time, and have some questions of my own now. I use the 12V train system, which I think is still the best of all, but I do like the 9V Metroliner that is coming out. Because of this, (...) (23 years ago, 5-Aug-01, to lugnet.trains)

4 Messages in This Thread:



Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

Custom Search

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR