  Re: Electrical Things (was: Railroad Dilemma)
 
(...) it on a scope. If we have a PWM voltage with a 50% duty cycle and 10 millisecond period An analog voltmeter will report the average voltage of 4.5, not 5 milliseconds DC 9V and 5 milliseconds DC 0V because it does not have the timescale (...) (26 years ago, 8-Mar-99, to lugnet.trains)
 
  Installing Track Designer
 
Since I released Track Designer 2.0 I've had a number of people email me saying that after they install it says it can't find the registry.tdl file. Why is this? I've never got to the bottom of it and despite requests no one has ever told me if (...) (26 years ago, 8-Mar-99, to lugnet.trains)
 
  Re: Electrical Things (was: Railroad Dilemma)
 
(...) That is because there is a diode to protect from reverse voltage and the voltage drop is about 0.3V (...) The maximum current is about 0.7A MAXIMUM ( maximum voltage and whell not turning) with one controller (...) the internal resistance will (...) (26 years ago, 8-Mar-99, to lugnet.trains)
 
  Re: Electrical Things (was: Railroad Dilemma)
 
(...) So would I, because it's not true! As I've said this many times, it's plain and simple variable DC voltage with 6 steps. Look at... (URL) (...) Also not true. The resistance of the motor is not enough to determine the current it will draw (...) (26 years ago, 8-Mar-99, to lugnet.trains)
 
  Re: Original wagon designs
 
Larry Pieniazek wrote in message <36E3BEC5.743B03BE@v...er.net>... (...) Looking at the pictures, it appears that all three covers are slideable (sp) . There are handles on both end covers. George (26 years ago, 8-Mar-99, to lugnet.trains)
 
  Re: Electrical Things (was: Railroad Dilemma)
 
(...) If you have any URL's where people have reported on this, I'd be interested. (...) Yep - it was ohmmeter across unpowered moter. I did think about directly measuring the current with the motor running, but my multimeter has a maximum current (...) (26 years ago, 8-Mar-99, to lugnet.trains)
 
  Re: Electrical Things (was: Railroad Dilemma)
 
(...) I'm not sure I agree that the voltage is variable. People have reported (via oscilloscope analysis) that it's pulse width modulated 9V instead. This will read on an analog meter like a low voltage, because it's taking the average across time. (...) (26 years ago, 8-Mar-99, to lugnet.trains)
 
  Re: Railroad Dilemma
 
How have you got this working? I sat down and had a long think about it last night, and played checked out my points with a multimeter to see which circuits get broken when you move the points, and I can see that you need to cut the rail on both (...) (26 years ago, 8-Mar-99, to lugnet.trains)
 
  Electrical Things (was: Railroad Dilemma)
 
I finally got round to having a play with my controllers and my multimeter. PUTTING TWO CONTROLLERS ON THE SAME TRACK ---...--- Firstly, apologies to Ben, who suggested if you connect two controllers to the same track, then they'd short only if the (...) (26 years ago, 8-Mar-99, to lugnet.trains)
 
  Re: Original wagon designs
 