  Re: Can the touch sensor be used as a momentary switch? (without RCX)
 
(...) It will work neither with a motor nor with a lamp (I tried that). The switch is made from conductive rubber whose resistance is too high (several hundred ohms). Jürgen (25 years ago, 27-Dec-00, to lugnet.robotics, lugnet.technic)
 
  Re: Revamped webpages
 
Gah! totally my fault. Okay, the images should all work now.... Tobbe Arnesson <tnt@arnesson.nu> wrote in message news:3a49f678.190182...net.com... (...) page, (...) (25 years ago, 27-Dec-00, to lugnet.technic)
 
  Re: Can the touch sensor be used as a momentary switch? (without RCX)
 
Shit, the white spaces haven't the same size as in the editor. (perhaps better now) ^ 1 O_/_O 4 | | 2 O O 5 3 O O 6 Rainer (25 years ago, 27-Dec-00, to lugnet.robotics, lugnet.technic)
 
  Re: Can the touch sensor be used as a momentary switch? (without RCX)
 
(...) I may be wrong, but I opened one of them and don't find any resistor ?!?! Are there perhaps different versions of touch sensors ?? Or is the black contact in the switch the resistor ?? (Or is a 500 ohm resistor in the RCX at its input ?) (...) (25 years ago, 27-Dec-00, to lugnet.robotics, lugnet.technic)
 
  Re: Can the touch sensor be used as a momentary switch? (without RCX)
 
(...) It's like this : ^ 1 O_/_O 4 | | 2 O O 5 3 O O 6 ^ - marks the yellow button _/_ should be the switch 1 and 2 are connected 4 and 5 are connected the switch is between 1 and 4 (or 2 - 4 or 1 - 4 or 1 - 5) Understandable ???? Rainer (25 years ago, 27-Dec-00, to lugnet.robotics, lugnet.technic)
 
  Re: Can the touch sensor be used as a momentary switch? (without RCX)
 
"Tony Hafner" <hafhead@PANTSplanetquake.com> wrote in message news:G67yvA.LJ0@lugnet.com... (...) a (...) I (...) No, since it contains a 500 ohm resistor it wouldn't make a very good switch. -a (25 years ago, 27-Dec-00, to lugnet.robotics, lugnet.technic)
 
  Re: Can the touch sensor be used as a momentary switch? (without RCX)
 
(...) I've been thinking about this. It would be great to use it as a switch but I haven't found the logic in it yet. I've used some trial and error to try to find the correct wire positioning but I think I'll have to bring out my multimeter and (...) (25 years ago, 27-Dec-00, to lugnet.robotics, lugnet.technic)
 
  Re: Revamped webpages
 
(...) Dito on the walker... /Tobbe (25 years ago, 27-Dec-00, to lugnet.technic)
 
  Re: Disappearing threads?
 
(...) Got the same problem... (...) I use Forté Free Agent and some headers disappear after a while (logic yet to be found), I simply select the requested group/groups and select "Online" | "Get all headers in selected groups" Hope this helps. (...) (25 years ago, 27-Dec-00, to lugnet.technic)
 
  Re: 8458 Silver Champion width
 
(...) Then it was just the shop display that had a solid tire as we thought. To bad actually. I don't think the Technic wheels can carry enough weight w/o tending to look like they've got a flat. 8462 Tow Truck wheels not counted for since they have (...) (25 years ago, 27-Dec-00, to lugnet.technic)


Next Page:  5 more | 10 more | 20 more

Redisplay Messages:  All | Compact

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR