Subject:
|
Re: About SetSerialComm(SERIAL_COMM_DEFAULT);
|
Newsgroups:
|
lugnet.robotics.rcx.nqc
|
Date:
|
Sat, 8 Sep 2001 18:26:30 GMT
|
Viewed:
|
2622 times
|
| |
| |
hi Zhengrong,
Sorry, I didn't understand (or read) your message well,
I thought you were looking for communicating with a PC.
Well as far as my knowledge reaches, I agree with Dave, the RCX can't receive raw data
(except for program downloading, which is packed as a whole).
I think you should use an other operating system, like Legos (or crack the firmware)?
Why do you want to communicate with raw data, is the speed to slow ?
I myself found the IR possibilities quiet limited. I'm working at the moment on a
general purpose IR-module, which can work on one side as a PC-IR-tower, and on the
other hand can work as a sensor / actuator for IR communicating (remote audio / video
controling by the RCX is my first goal).
Zhengrong Zang wrote:
> Hi Stef,
> I read your page, but I can't find what I need, I want to know how to
> communicate between RCXs with raw data (without header 55,ff,00), I don't
> care to communicate between Rcx and PC.
> You can read Dave's message, it seems he is also sure how to receive raw
> data, can you give me more idea?
>
> Zhengrong
>
> In lugnet.robotics.rcx.nqc, Stef Mientki writes:
> > hi Zhengrong,
> >
> > probably Dave answered your question, but I didn't see his answer in this
> > newsgroup.
> > I'v done some tests with different serial protocols and different baudrates,
> > see
> >
> > http://baserv.uci.kun.nl/~smientki/Lego_Knex/Lego_electronica/Data_acquisition.htm
> >
> > maybe it's of some use to you.
> >
> > Zhengrong Zang wrote:
> >
> > > Hi, Dave
> > > In your NQC Guide, there is a text about this function "The default is to
> > > send data at 2400 baud using a 50% duty cycle on a 38kHz carrier.", how
> > > about other settings, for example, parity and stop bit, is it odd parity
> > > without stop bit?
> > > Then I want to know if the SendSerial(start, count) sends raw data without
> > > any header, for example 55, ff, 00 and so on, could you help me?
> > >
> > > Br
> > > Zhengrong
> >
> > best regards,
> > Stef Mientki
|
|
Message has 1 Reply:
Message is in Reply To:
| | Re: About SetSerialComm(SERIAL_COMM_DEFAULT);
|
| Hi Stef, I read your page, but I can't find what I need, I want to know how to communicate between RCXs with raw data (without header 55,ff,00), I don't care to communicate between Rcx and PC. You can read Dave's message, it seems he is also sure (...) (23 years ago, 8-Sep-01, to lugnet.robotics.rcx.nqc)
|