| | Re: NQC 1.0 compatibility mode
|
|
(...) I think if they need NQC V1, they won't have this new IDE. If they have the new IDE, they won't have NQC V1.x (20 years ago, 7-Jan-05, to lugnet.robotics.rcx.nqc)
|
|
| | NQC 1.0 compatibility mode
|
|
Would anyone miss terribly the NQC 1.x compatibility mode if I were to remove it? At this point it seems like it is a very useless feature, but maybe someone out there is still using the 1.x API. What do you think? John Hansen (20 years ago, 6-Jan-05, to lugnet.robotics.rcx.nqc)
|
|
| | Re: Swan Firmware
|
|
(...) The Swan firmware is Dick Swan's replacement firmware which is compatible with the standard LEGO firmware (firm0328.lgo). The Swan firmware is available at the link mentioned in this post: (URL) use swan.nqh (available in the zip file (...) (20 years ago, 4-Jan-05, to lugnet.robotics.rcx.nqc)
|
|
| | Re: Swan Firmware
|
|
(...) what is the swan firmware? what have I missed? Thomas (20 years ago, 4-Jan-05, to lugnet.robotics.rcx.nqc)
|
|
| | Re: questions on events
|
|
(...) This is where you use the event fork(s) that you asked about in a different message. You nest these forks to determine which event has been triggered. (...) Robolab is just a LabVIEW program. Viewed in that context, it is an amazing bit of (...) (20 years ago, 3-Jan-05, to lugnet.robotics.rcx.robolab, lugnet.robotics.rcx.nqc)
|
|
| | Re: questions on events
|
|
(...) Yeah, my fault. I said two things that do not have to follow. Yes, you can use one event monitor to watch more than one event... and yes, you can't nest event monitoring statements. I've not used an event watcher to monitor more than one event (...) (20 years ago, 3-Jan-05, to lugnet.robotics.rcx.robolab, lugnet.robotics.rcx.nqc)
|
|
| | Swan Firmware
|
|
I have installed the new Swan Firmware via Brixcc 3.3.7.8 using standard nqc coding works ok. I'm having problems trying to include any of the new code. Question 1 How do we use the Swan.nqh file Question 2 Can we use the new variables defined in (...) (20 years ago, 3-Jan-05, to lugnet.robotics.rcx.nqc)
|
|
| | RE: Formula container?
|
|
Ok, I got it... Thanks to the Tufts site. (URL) is kind of odd that the navigation is to "create ---> constant"... "constant?" Hmmm... -- E (...) (20 years ago, 3-Jan-05, to lugnet.robotics.rcx.robolab, lugnet.robotics.rcx.nqc)
|
|
| | Formula container?
|
|
I am trying to compare the light value of two sensors, namely s1, & s2 . I don't want to go through the long route which is to save the light values from different sensors to different container, then, compare them. How about using "formula (...) (20 years ago, 3-Jan-05, to lugnet.robotics.rcx.robolab, lugnet.robotics.rcx.nqc)
|
|
| | RE: questions on events
|
|
(...) Hmm..., notice that the start monitoring icon allows to watch for multiple events within the same task. If each task can only monitor a single event, that feature being there does not quite make sense. (...) This is why I suspect the "event" (...) (20 years ago, 3-Jan-05, to lugnet.robotics.rcx.robolab, lugnet.robotics.rcx.nqc)
|