| | Re: Spirit.ocx
|
| "Don Beauchesne" <dcbeau@NoSpam.shaw.ca> wrote in message news:Hvq79y.1A9I@lugnet.com... (...) (I (...) problem (...) only the (...) Try this link for some help: (URL) -bm www.brickmodder.net (21 years ago, 6-Apr-04, to lugnet.robotics.rcx.nqc)
| | | | Spirit.ocx
|
| I'm trying to use the spirit.ocx ActiveX control and VB to program my RCX (I realize this is a NQC newsgroup, but I didn't see one for VB users). My problem is that my infrared tower runs off the USB port, but spirit.ocx exposes only the serial (...) (21 years ago, 6-Apr-04, to lugnet.robotics.rcx.nqc)
| | | | Re: NQC's future
|
| (...) I probably botched the DOS serial driver, but you could give this build a try. (Requires at least a 386) (URL) had the djgpp version of gcc lying around from a previous DOS project, so I thought I'd give it a shot. Don (21 years ago, 3-Apr-04, to lugnet.robotics.rcx.nqc, lugnet.robotics.spybotics)
| | | | Re: NQC's future
|
| (...) I'm not likely to ever attempt such thing. Sorry about that. Maybe someone else will. John Hansen (21 years ago, 2-Apr-04, to lugnet.robotics.rcx.nqc, lugnet.robotics.spybotics)
| | | | Re: NQC's future
|
| (...) Call me kooky, but I'd like to see actual DOS support (ie, non-Win32s specific code) for the serial port. I have an old, trusty Win3.11 laptop that I want to use when taking my RCX out to events, for last minute fiddling. I've found version (...) (21 years ago, 2-Apr-04, to lugnet.robotics.rcx.nqc, lugnet.robotics.spybotics)
| | | | Re: RCX to Spy messages thru IR communications route
|
| (...) Hi John, It does work. The RCX appears in the Spybot's World Table. The Range is set to Anywhere. Pretty cool... --Jay (21 years ago, 29-Mar-04, to lugnet.robotics.spybotics, lugnet.robotics, lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)
| | | | Re: RCX to Spy messages thru IR communications route
|
| (...) Boy, this RCX to Spy IR comm thing is sure going the right way! The SPYBOTICS are a little known and hidden LEGO gem. Gramps Eddie & Grandson CJ (21 years ago, 26-Mar-04, to lugnet.robotics.spybotics, lugnet.robotics, lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)
| | | | Re: RCX to Spy messages thru IR communications route
|
| (...) I presume that somewhere that data is being dropped. It isn't showing up as data the tower reports to the operating system. I haven't actually tried the function I posted the other day so it is entirely possible that a Spybot will not (...) (21 years ago, 26-Mar-04, to lugnet.robotics.spybotics, lugnet.robotics, lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)
| | | | Re: RCX to Spy messages thru IR communications route
|
| I'm a little surprised that the Spybot doesn't need to see the packet header byte - the byte containing the range/orientation bits preceding the 0x8n Ping byte. The header is deliberately generated with the stop bit cleared to force a framing error. (...) (21 years ago, 25-Mar-04, to lugnet.robotics.spybotics, lugnet.robotics, lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)
| | | | Re: RCX to Spy messages thru IR communications route
|
| (...) Yes, that is what another person told me via email yesterday. So a ping simulation function for an RCX running the RCX2 firmware could be: // nLinkID = 0-7, where 0 = no link, 7 = pc link, 1-6 = controller link // nMyID = 8-255 (minBotID = 8, (...) (21 years ago, 25-Mar-04, to lugnet.robotics.spybotics, lugnet.robotics, lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)
| |