    communication PC <-IR-> RCX —Pavel Petrovic
   Does anybody have an example of a LegOS program that sends data back from the RCX to the PC? Is this possible also with SPIRIT.OCX poll/datalog protocol? Tnanks, Pavel. e-mail: petrovic@ifi.ntnu.no (25 years ago, 11-Nov-99, to lugnet.robotics.rcx.legos)
   
        Re: communication PC <-IR-> RCX —Sergey Ivanyuk
     (...) You can use lnp_logical_write. But - the IR tower automatically turns off if nothing has been sent through it, so in order to see the data coming in, you have to keep sending something through the tower. [...] -- Regards, Modemch (25 years ago, 11-Nov-99, to lugnet.robotics.rcx.legos)
   
        Re: communication PC <-IR-> RCX —Markus L. Noga
   Hi Pavel, check out the program loader. Basically, you have to register your own port handler for incoming packets on the PC. You should also acknowledge them in some way, so the RCX knows what's going on. Maybe IR networking should become secure. (...) (25 years ago, 11-Nov-99, to lugnet.robotics.rcx.legos)
 