| | Re: Rom sensor read routine Markus L. Noga
| | | Hi Kekoa, (...) I am fixing this right now. (...) The current legOS sensor read cycle is this (i=illuminate, c=A/D conversion) S1: iii iii iii ccc S2: ccc iii iii iii S3: iii ccc iii iii S4: iii iii ccc iii If you find your sensor 2 readings to be (...) (26 years ago, 2-May-99, to lugnet.robotics.rcx.legos)
| | | | | | | | Re: Rom sensor read routine Kekoa Proudfoot
| | | | | (...) The current LegOS model really hammers the sensors, almost to the point of oversampling them. It only takes a short while (less than 0.1 ms, I think) to sample all four sensors; I think LegOS samples the next sensor immediately after finishing (...) (26 years ago, 13-May-99, to lugnet.robotics.rcx.legos)
| | | | | | |