To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcx.legosOpen lugnet.robotics.rcx.legos in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / legOS / 1955
  Re: Is this an error in legOS 0.2.5?
 
So in the original firmware, the system is shut down if ultra-low battery is detected. If we don't want tot do that, we could change the ">" in the 2nd compare to a "<" to get some hysteresis. Or would it be usefull to stop legOS and do a shut-down (...) (23 years ago, 29-Jul-01, to lugnet.robotics.rcx.legos)
 
  Re: Is this an error in legOS 0.2.5?
 
(...) ultra-low (...) Would that really make sense? Since changing batteries destroys all memory, the program will not survive despite advance warning about the impending doom of battery low. In effect, changing the batteries is equivalent to the (...) (23 years ago, 30-Jul-01, to lugnet.robotics.rcx.legos)
 
  Re: Is this an error in legOS 0.2.5?
 
(...) Hmmm, yes, you are right. In fact it woudn't make sense. My actual robot uses a little neural net and if battery goes low, the actual data will be sent to the PC to be saved. For this, it would be nice if the RCX makes some noise, I grab it, (...) (23 years ago, 31-Jul-01, to lugnet.robotics.rcx.legos)
 
  Re: Is this an error in legOS 0.2.5?
 
(...) a (...) Maybe, if you wanted to be really flash, when you get the (non-ultra) low battery warning, your robot could start seeking out the tower, and get ready to send the data. Maybe have a light near the tower that starts flashing when it (...) (23 years ago, 4-Aug-01, to lugnet.robotics.rcx.legos)