  Re: power levels clarification
 
(...) Others have explained Pulse Width Modulation. However, if the kids are old enough to understand the difference between linear (straight line) and square law (curving ever upwards) and electrical voltage, resistance and power, you could say (...) (20 years ago, 13-Mar-05, to lugnet.robotics.rcx, lugnet.robotics.rcx.robolab)
 
  Re: power levels clarification
 
Hi Mark, (...) is it really true that there is a square law for PWM? Can you explain the reason why this is so? I understand that this is true if you change the voltage (half the voltage gives half the current so a quarter of the power). But I (...) (20 years ago, 14-Mar-05, to lugnet.robotics.rcx, lugnet.robotics.rcx.robolab)
 
  Re: power levels clarification
 
(...) I couldn't call myself an expert either! In your second way of looking at it, the full voltage and full current are already multiplied to give full power for part of the time. I=(Vcc-Eb)/R Current I, Voltage Vcc, Back EMF Eb and motor (...) (20 years ago, 14-Mar-05, to lugnet.robotics.rcx, lugnet.robotics.rcx.robolab)