Hi Tom,

Just for my education purpose,  I'd like to understand the difference
between the "begin" & "end" control boxes at the "Front Panel" window.
Although they look identical, they must be different since they failed to
wire to the blocks next to them once  I switched them at the block diagram
window (the program window).

--thanks
E
> -----Original Message-----
> From: news-gateway@lugnet.com
> [mailto:news-gateway@lugnet.com] On Behalf Of Thomas Johnson
> Sent: Sunday, January 16, 2005 4:01 PM
> To: lugnet.robotics.rcx.robolab@lugnet.com;
> lugnet.robotics.rcx@lugnet.com
> Subject: Re: sub-vi begin vs end control
> 
> In lugnet.robotics.rcx.robolab, Elizabeth Mabrey wrote:
> > Hi,
> > 
> > After a sub-vi is created, there are two controls created • namely begin
> > and end.  Would someone explain why they are backwards? • That means,
> > it creates an "end" control linked to the beginning of the sub-vi,
> > while the "begin" at the end.
> 
> It is a leftover from LabVIEW.  When you create a sub.vi,
> LabVIEW reuses the name of whatever is wired to the
> control/indicator.  This behavior makes perfect sense in
> LabVIEW but much less so in Robolab.  FWIW, the names are
> little more than labels and you can change them as you see fit.
> 
> Tom
> 



Message has 1 Reply:
  Re: sub-vi begin vs end control
 
(...) In a LabVIEW program (vi) there is a front panel and a block diagram. The front panel is the user interface and contains both controls and indicators. When you place a control/indicator on the front panel a corresponding terminal is created on (...) (22 years ago, 17-Jan-05, to lugnet.robotics.rcx.robolab, lugnet.robotics.rcx)

Message is in Reply To:
  Re: sub-vi begin vs end control
 
(...) It is a leftover from LabVIEW. When you create a sub.vi, LabVIEW reuses the name of whatever is wired to the control/indicator. This behavior makes perfect sense in LabVIEW but much less so in Robolab. FWIW, the names are little more than (...) (22 years ago, 16-Jan-05, to lugnet.robotics.rcx.robolab, lugnet.robotics.rcx)

5 Messages in This Thread:


Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact

This Message and its Replies on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR