| | RE: Custom Firmware, IR Problems, and Dead RCXs (long)
|
| (...) Actually, there's a regulator on the Tower that takes the voltage for the digital side to +5 and keeps it there. The capacitor is only rated for 10V. The higher voltage will allow higher current through the IREDs as they are connected right to (...) (23 years ago, 26-May-01, to lugnet.robotics.rcx)
| | | | RE: Custom Firmware, IR Problems, and Dead RCXs (long)
|
| Even more interesting.... I've also just replaced the IRED I replaced a few hours ago in my RCX :-( This time, I'm putting a limiting resistor between the IREDs in the RCX to keep the current within limits. The following is pure conjecture on my (...) (23 years ago, 26-May-01, to lugnet.robotics.rcx)
| | | | Re: Custom Firmware, IR Problems, and Dead RCXs (long)
|
| (...) Maybe this is shedding some light on why LEGO removed the Power Port in the 1.5's. To remove a known problem without dealing with it.?.?.? Dean -- Coin-Op's For Sale!: (URL) Lego Workshop: (URL) Lego Club: (URL) (23 years ago, 26-May-01, to lugnet.robotics.rcx)
| |