To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcxOpen lugnet.robotics.rcx in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / *3930 (-10)
  Cybermaster: Cannot receive though sending works (w/o sprit.ocx)
 
Hi, I've written a small Visual Basic program so I can use Cybermaster under Windows 3.1x. (So I cannot use spirit.ocx.) Sending commands works (motor on/off, sound, etc.). But I don't get any echo. I cannot get any sensor data, and I can't see if (...) (24 years ago, 22-Jan-01, to lugnet.robotics, lugnet.robotics.cybermaster, lugnet.robotics.rcx)
 
  Re: Interfacing Sharp's GP2D02 Distance Sensor to the RCX
 
Hi, I asked this problem a few weeks (or months??? ... I don't know a what time ...) but nobody could help. I got the same following answer ".... the sensor takes 35 mA and this is to much for the RCX ..." but I couldn't understand this at this (...) (24 years ago, 21-Jan-01, to lugnet.robotics, lugnet.robotics.rcx)
 
  RE: Anyone made animatronics with the RCX yet?
 
(...) I know this only works with pbForth, and it's not ALL Technic, but you can drive standard servos with the RCX. Here's how: (URL) You can even drive pneumatic switches with the servos... Cheers, Ralph Hempel - P.Eng ---...--- Check out pbFORTH (...) (24 years ago, 21-Jan-01, to lugnet.robotics.rcx)
 
  Re: Anyone made animatronics with the RCX yet?
 
(...) I tried to have my Raptor puppet set up with Pneumatics but I gave up because I couldn't find a decent way of triggering it. The ways I had it were way to slow and painful. Has anyone come up with a great way of using pneumatics with (...) (24 years ago, 21-Jan-01, to lugnet.robotics.rcx)
 
  Re: LegOS 0.2.5 and LNP
 
(...) Ok. Checking and testing never hurts :-). (...) It's not for performance, but for correctness. The old code was like this: if(lnp_addressing_ha...ler[port]) { ... lnp_addressing_handl...th-2,src); You first test lnp_integrity_handler and then, (...) (24 years ago, 21-Jan-01, to lugnet.robotics.rcx.legos)
 
  Re: LegOS 0.2.5 and LNP
 
(...) you may see (...) give access (...) the handlers (...) My only (...) depend on. (...) introduce a (...) this point to (...) I think that we can use safely (CONF_TM || defined CONF_HOST) condition. I'm checking the whole patch and I think that (...) (24 years ago, 21-Jan-01, to lugnet.robotics.rcx.legos)
 
  Anyone made animatronics with the RCX yet?
 
I'd like to make some sort of Disney-style animatronic robot with my RCX. This would involve using all three motors to control a Tiki Room-style parrot, for example, with a rotation sensor on each motor. Programming the robot would involve running a (...) (24 years ago, 21-Jan-01, to lugnet.robotics.rcx)
 
  Re: RCX 1.0 Power Jack/AC Adapter Question
 
(...) I've ran my RCX 1.0 on a train power adapter for 2 weeks straight. No problems. Dean -- Coin-Op's For Sale!: (URL) Lego Workshop: (URL) Lego Club: (URL) (24 years ago, 21-Jan-01, to lugnet.robotics.rcx)
 
  Re: RCX 1.0 Power Jack/AC Adapter Question
 
You can use any of the AC adapters from the 9V train sets on the RCX 1.0. I use the ac adpaters from the 4561 and the feight train (red and black) and I have never had any problems. Ahui (...) (24 years ago, 21-Jan-01, to lugnet.robotics.rcx)
 
  RCX 1.0 Power Jack/AC Adapter Question
 
I just snagged another 4561Railway Express. I believe I recall reading that the AC adapter in that will work with my RCX 1.0. Can anyone confirm this? Thanks, Thomas (24 years ago, 21-Jan-01, to lugnet.robotics.rcx)


Next Page:  5 more | 10 more | 20 more

Redisplay Messages:  All | Compact

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR