Subject:
|
Re: problem with sonar
|
Newsgroups:
|
lugnet.robotics.handyboard
|
Date:
|
Wed, 15 Mar 2000 21:12:31 GMT
|
Original-From:
|
Gary Livick <glivick@pacbell.net/AvoidSpam/>
|
Viewed:
|
1389 times
|
| |
| |
A 470 microfarad electrolytic capacitor across the power leads to the sonar board
will probably fix your problem. You can get a lot of current really fast out of
one of those things. I remember charging them up and tossing them to one of my
friends in lab class. Obviously another story.
Gary Livick
Tiny HC11 products for your robot
http://www.teleport.com/~raybutts/
Way Lam wrote:
> Hi.. I have a problem with ultrasonic sonar power supply, hope anyone can help
> me.. thanks..
> I run my sonar well with the exp. board using transformer, but i failed to run
> it together with 2 sharp GP2D02 IR, i think may due to 2.5A surge of the sonar,
> so i want to use external power for the sonar, can anyone tell me where can i
> locate the power in the HB or exp. board ?? or do you have any other idea for
> me ?? thanks...
|
|
Message is in Reply To:
| | problem with sonar
|
| Hi.. I have a problem with ultrasonic sonar power supply, hope anyone can help me.. thanks.. I run my sonar well with the exp. board using transformer, but i failed to run it together with 2 sharp GP2D02 IR, i think may due to 2.5A surge of the (...) (25 years ago, 15-Mar-00, to lugnet.robotics.handyboard)
|