Subject: 
Help with IR receive
Newsgroups: 
lugnet.robotics.handyboard
Date: 
Fri, 17 Dec 1999 04:10:42 GMT
Viewed: 
595 times
  
I just added the Sharp IS1U621 to my handyboard. That is apparently a substitute
for the ISU160. When I run the simple test program:

    while (1) {if (4 & peek(0x1000)) fd(0); else bk(0);}

my lights continuously flicker. When I put my logic proble on the output, it is
a continuous pulse. The demodulator does not seem to be working. I also tried a
second part with the same result.

The data sheet for these parts seems to indicate the need for some capacitors on
the supply and output (47uF and 1000pF respectively)

Can anyone give me some ideas?

thanks,

Wayne



Message has 1 Reply:
  Re: Help with IR receive
 
(...) substitute (...) These are NOT optional components. I saw the same thing with the IS1U60 if I didn't use the 47uf/47ohm low-pass filter on the Vdd input to the part. Use it, your problem will go away. have fun, DLC (25 years ago, 17-Dec-99, to lugnet.robotics.handyboard)